The AUTODEC® ROTO therapeutic support surface provides effective and other solutions for a wide patient management issues. Alternating pressure relief combined with advanced rotation therapy and moisture management – all in one system.
Adjustable rotation angles up to 30⁰ and times. Dual compressor pump provides better performance. The pump can operate in the following modes: pressure alternating, static, pulsating or full inflation mode. The system has the Advanced Turn Technology function, i.e. lateral tilts and continuous patient rotation (one- or two-sided).
Lateral tilt and rotation can be carried out during each operating mode. The replacement mattress is made of transverse removable cells and equipped with side bolsters to protect the patient from both sides.
AUTODEC® ROTO is recommended for round-the-clock pressure ulcer prevention and management of all pressure ulcer stages.
ANTI-DECUBITUS ALTERNATING PRESSURE MATTRESS
Model: AUTODEC® ROTO ADR100F-21011AF
Manufacturer and advertising entity: PPH „Real”, ul. Kasztanowa 27 10-156 Olsztyn, Poland
Product usage: prevention and / or treatment of pressure ulcers of all categories.
Dual compressor pump can operate in four different modes:
A built-in pressure controller automatically adjusts the mattress settings. Pressure can be also adjusted manually. The mattress will work in Auto Set mode until it’ll be switched to the manual adjustment mode.
Function of lateral tilt and patient rotation operating in both alternating and static modes. This feature not only improves the prevention and treatment of pressure ulcers, but also assists with pulmonary functions and reduces the manual handling. The turn time can be adjusted from 10 to 95 minutes (5min. intervals) with options to turn right or left only, as well as both sides, up to 30⁰. The facility can be turn on or off using control panel, in accordance to the needs of users
BENEFITS:
Cells in head section are always inflated for better comfort.
In conventional micro air loss systems the air is coming through the micro holes made in cells, but patient’s body blocks the holes and reduces the effectiveness. The iMAL system is located beneath the mattress cells and is not interfered with patient’s body.
Independent micro air loss system reduces heat accumulated in the mattress, which increases patient comfort and ensures proper microclimate around his body. The iMAL system is independent from mattress cells and therefore it does not interfere with transport functions. The iMAL system works automatically and does not require any settings.
*An audible alarm will sound unless cancelled by the mute button. If the cause of alarm is not removed, the alarm will sound again.
Prevents from accidental or unintentional setting changes on the pomp. After a period of inactivity the control panel will automatically lock.
Oorder code: ADR100F-21011AF
MATTRESS REPLACEMENT | |
Number of cells | 18 |
Cell material | TPU |
Cover material | poliester-PU |
Mattress base material | poliester-PU |
Max patient weight | 255kg |
PUMP | |
Dimensions | 42,7 x 12,8 x 23,3cm |
Case material | ABS |
Mode of operation | continous |
Supply voltage/frequency | 230V/50Hz |
Power output | 35 VA |
Operating cycle times | 10, 15, 20minutes |
Tilt/rotation time | 10-95min (5min. intervals) |
Degree of protection against Electrical shock | Class II, type BF |
Degree of protection of ingress of liquids | IP21 |